Glass

Glass roof systems with perfect air and water tightness

Text Lieke BousemaImage Kingspan Light + Air

Kingspan Light + Air bouwt mee aan de nieuwe Klimatenkas van Hortus Botanicus Amsterdam, waarbij daglichttoetreding en een sterk verbeterde isolatie centraal staan.
Kingspan Light + Air bouwt mee aan de nieuwe Klimatenkas van Hortus Botanicus Amsterdam, waarbij daglichttoetreding en een sterk verbeterde isolatie centraal staan.

Airtight construction is inextricably linked to sustainable building. It encompasses all the regulations, calculations, systems and methods of construction aimed at sealing air leaks in the building envelope. “Limiting air permeability is essential to keep heat inside, save energy, improve comfort and prevent problems with moisture, draughts and noise,” says Jan-Willem Hermans, Technical Manager at Kingspan Light + Air. “Our glass roof systems naturally support this, and are continually being developed, with the overall insulation value of the glass, glazing bars and connections in mind.”

“Even if you select the best glass roof system with the best glazing, the overall thermal insulation is compromised if the connections between the upstand and the flat roof are not properly sealed,” explains Jan-Willem. “Kingspan Light + Air addresses these problems using EPDM seals, which provide excellent air and water tightness. A strip of insulation material then prevents cold air from reaching the inner profile.” 

The insulation value (Uw value) of a glass roof system is determined by the U-value of the glass (Ug value), the U-value of the glazing bar (Uf value) and heat loss through the spacers in the insulating glass unit (Ψ value).

A good, seamless connection

One major advantage of EPDM seals over, for example, pre-compressed sealing tape is their size, says Jan-Willem. “The continuous seals can be laid more neatly over the upstands, ensuring a good, seamless connection. EPDM also provides better air and water tightness.”

Efficient water drainage

“Our cover caps are of high quality,” emphasises Jan-Willem. “Even so, they cannot guarantee 100% water tightness. A minimal amount of water will always infiltrate the glazing bar system. However, a special design ensures that this water is efficiently drained out through the water channel in the head of the glazing bar. The water channel acts as a sort of outlet.”

Improved clamping

An important development in Kingspan Light + Air’s glass roof systems concerns the clamping. “In glass roof systems, the glass pane is fitted on one side of the profile, while an opaque panel is installed on the other,” says Jan-Willem. “This panel must be the same thickness as the pane, but in practice it is often thinner. A hard plastic block compensates for this difference and also reduces heat transfer through the profile. Adding foam rubber to the glazing rebate also makes a significant contribution.”

The new platform canopy at Ede-Wageningen station comprises 23 spruce triangles, with smaller triangles formed within them using rooflights and opaque panels.

Vacuum glazing with a constant Ug value

The insulation value (Uw value) of a glass roof system is determined by the U-value of the glass (Ug value), the U-value of the glazing bar (Uf value) and heat loss through the spacers in the insulating glass unit (Ψ value), says Jan-Willem. “One challenge is that there is no strict European product standard (CE standard) for glass roofs. In addition, the slope of double or triple glazing affects the Ug value. Clients need to be aware of this so that like-for-like comparisons can be made.” Kingspan Light + Air is currently developing a system with a very good Ug value that remains constant in every position, making a Uw value of 0.5 possible in a glass roof system.

Leading the way on regulations

Kingspan Light + Air recently successfully tested its glass roof system for resistance to flying brands, says Jan-Willem. “Our organisation holds the VMRG quality mark. At European level, VMRG is working to extend the standard for curtain walling to glass roof systems. In anticipation of this, we have already carried out all the relevant tests in accordance with the National Assessment Guideline for the KOMO® Certificate for rooflights and roof glazing (BRL 0105). These cover wind and water tightness, wind tightness, the U-value of the glazing bar (Uf value), sound insulation and resistance to flying brands. This puts us ahead of the market and guarantees the quality of our glass roof systems.” All test reports are available on request.  

Een zakelijke vraag aan Kingspan Geïsoleerde Panelen – Kingspan B.V.? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeGlass for light and comfort
  • SubjectGlass
  • CompanyKingspan Geïsoleerde Panelen – Kingspan B.V.
Share this article

Advertisement

Follow Gevelbouw

Follow