Tilt-and-turn windows installed at the edge of a floor must, under the Besluit bouwwerken leefomgeving (Bbl), have a non-movable barrier. This is required where the adjoining floor, ground or water is more than one metre lower, to prevent someone falling through the window. At the window, this barrier must be at least 0.85 metres high, measured from the floor and taking into account any potential foothold. This requirement can be met by installing a transom at the correct height or by using a ‘French balcony’.
Instead of a non-movable barrier, a so-called ‘equivalent’ solution is to block the window’s turn function or to choose a window that only opens in tilt mode. However, these alternatives do not guarantee safety throughout the building’s entire service life and can therefore create life-threatening situations. The façade industry believes that a quality façade must be safe throughout the building’s entire life cycle. In a position paper, the façade industry organisations jointly call for safety to be made the top priority in façade design, and for optimal fall protection to be chosen in these situations: a non-movable barrier.
Life-threatening
In practice, tilt-and-turn windows are included in designs as floor guarding, with the turn function blocked so that only the tilt function works. There is no fixed fall protection, such as a French balcony, behind these windows. These locking devices have not been tested for resistance to tampering or durability, and users can often override them. This can create life-threatening situations, particularly given that these solutions are also used in residential towers.
Legislation
Article 4.20(1) of the Bbl requires a non-movable barrier where a floor is more than one metre above an adjoining floor, ground or water. The issue here is therefore the use of ‘equivalent’ solutions in place of a non-movable barrier. There may be debate over whether something is equivalent in the strict legal sense. However, safety is at stake, and a quality façade must be safe. VMRG has discussed this with the trade associations for plastic and timber windows and doors (VKG and NBVT) and the trade association for architectural ironmongery (VHS).

Can be tampered with
The trade associations are unanimous in their conclusion: blocking the turn function of a tilt-and-turn window as fall protection is not safe. Locking solutions can almost always be tampered with. In addition, the window sash must be accessible all the way around for maintenance. This means the turn restrictor has to be removed. There is no way to ensure that it is then refitted, or refitted correctly. Façade safety is assured by clear guidelines for façade elements. Products are extensively tested against these guidelines, and compliance is verified through quality inspections. It is not possible to test and verify a turn restrictor, because there are no guidelines or regulations for this type of application. French balconies are subject to fall protection requirements. They must be able to withstand a certain force if someone falls against them. This locking solution effectively assumes that the sash and its hardware can also withstand the impact of a fall. But this has never been tested, because no such test exists. Windows that only open in tilt mode cannot be safely used as floor guarding without a non-movable barrier either. They also need to be accessible all the way around for maintenance, and there are no fall protection tests for them either. It is therefore not possible to guarantee the safety of opening windows used as floor guarding without non-movable fall protection.
User safety
The façade industry therefore believes that fall protection in the form of a device that blocks the turn function of a tilt-and-turn window, or the use of a window that only opens in tilt mode without non-movable fall protection, should no longer be used. These applications do not provide the same level of safety as a non-movable barrier. In a position paper, the façade industry organisations jointly set out their position and supporting arguments. Fall protection must be guaranteed throughout the building’s entire life cycle. This cannot be achieved with opening windows unless a non-movable barrier, such as a French balcony, is added. The façade industry therefore calls on clients, designers, the competent authority and quality assurance bodies to follow the legislation to the letter when using a tilt-and-turn window as floor guarding, and to choose a non-movable barrier, such as a French balcony with railings or a glass panel, or a window with a transom at the correct height for fall protection. The safety of building users must always come first.
Question about this story? Ask your question