Het SlimFort gevelisolatiesysteem van IsoBouw voor een geventileerde gevelopbouw is met verschillende toepassingen in ‘end use application’ getest.
Het SlimFort gevelisolatiesysteem van IsoBouw voor een geventileerde gevelopbouw is met verschillende toepassingen in ‘end use application’ getest.

Test, test, test…. We have been hearing this more often lately, but not ‘just’ in relation to the fire safety of a façade build-up. Yet, according to Marco Buijk, technical engineer at IsoBouw Systems, it is essential to test as much as possible. Fire safety is the result of several factors working together, and certainly not the sum of the fire classes of the individual materials used.

IsoBouw supports testing a façade build-up in the so-called ‘end-use application’.

“Three materials with a reaction-to-fire class B do not necessarily mean that the combination will also achieve class B,” Buijk begins. “In fact, the result could even be worse. Nor can manufacturers ‘hide behind’ a reaction-to-fire class A1 or A2. Without demonstrable test results, these materials do not guarantee that the façade will achieve a B classification either. At IsoBouw, we therefore support testing a façade build-up in the so-called ‘end-use application’, in other words, the entire construction rather than the individual materials. Naturally, we have had our façade systems tested individually by independent laboratories such as Efectis and Warringtonfire, and also in combination with the most commonly used façade claddings.” 

IsoBouw has had its façade systems tested individually by independent laboratories such as Efectis and Warringtonfire, and also in combination with the most commonly used façade claddings.

IsoBouw’s SlimFort façade insulation system for ventilated façades has been tested in various ‘end-use applications’. Buijk says: “For example, we have had a build-up with Eternit sidings tested, as well as one with metal and composite materials. The great thing is that all combinations with competing façade claddings can also be covered by these tests. The results demonstrate a B classification for various façade systems using our SlimFort façade insulation, achieving the highest possible fire performance. For other specific applications, we can quickly liaise with the testing institutes to obtain a ‘classification without testing’ (CWT), based on all available scientific knowledge and previous tests, provided the build-up meets all the requirements, of course.”

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeSafe and verifiable facade construction
  • SubjectFaçade cladding
Share this article

Advertisement

Follow Gevelbouw

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.