Wind and water pressure and noise levels are key considerations

As cities expand, major urban centres are increasingly opting for high-rise buildings. The Netherlands already has more than 200 buildings measuring 70 metres or higher. That number will only continue to grow in the coming years. This trend calls for a sharp focus on the quality of skyline-defining structures during design, production and construction. Reynaers Aluminium, a manufacturer of innovative aluminium solutions for windows, doors and curtain walls, knows this better than anyone.

Reynaers Aluminium’s aluminium façade solutions are increasingly being used in high-rise projects, a discipline with requirements and considerations that differ somewhat from those of traditional low-rise construction. “When translating an architectural design into a technically feasible, buildable façade solution for a high-rise building, you always need to find a bespoke approach,” says project team leader Bart Hellings. “The same applies to façade elements. The VMRG standard, set by the trade association for service providers and manufacturers in the façade industry, provides us with valuable guidance. For example, when it comes to noise levels and wind and water pressure.”

Bart Hellings, project team leader at Reynaers Aluminium. (Photography: Reynaers Aluminium)

Water and wind

One of the main challenges is to preserve the architect’s design while also devising a façade that meets all the specified requirements. This makes it important to pay attention to the performance of the façade solution, particularly in high-rise buildings. “At a height of 100 metres, a façade is naturally exposed to greater wind and water pressure than in low-rise construction,” Bart explains. “This needs to be taken into account when selecting the windows, doors and façade during the project design. Often, it comes down to details, such as the seal between the aluminium and the building structure. Air permeability, wind resistance and watertightness can be tested at the test centre at Reynaers Campus in Duffel. This allows us to assess the façade’s performance in practice. In reality, we often find that an architect cannot take everything into account. Reinforcements, for example, are often needed to ensure stability, but are not always included in an architect’s initial design. Of course, standards and regulations apply when determining the design pressure and wind load on a façade, which help establish, among other things, where these reinforcements are needed. This calls for close collaboration with the architect or contractor during a building’s design phase. We therefore always recommend contacting the Reynaers Aluminium project team during the design process.”

Natural ventilation solution in Haasje Over. (Photography: Jan Willem Schouten)

Noise levels 

High noise levels are often an issue in places where high-rise buildings are being developed, such as busy city centres. “The preferred noise limit set by the Noise Abatement Act is often exceeded,” says Bart. “In many cases, municipalities therefore require homes in such locations to have at least one quiet façade, so that residents can, for example, open a window at night without being disturbed by noise.” Some municipalities also require noise levels on outdoor spaces to remain below a certain number of decibels at all times. This presents a challenge for single-aspect homes or homes exposed to high noise levels. However, various solutions are available, such as adding a balcony or loggia, sound-insulating vents or glass balustrades. The new MasterLine 8 POW SoftTone window also provides natural ventilation through a sound-insulating yet porous panel. “We are increasingly working with architects to find bespoke solutions, as we did for Haasje Over by VMX Architects,” Bart continues. “A new profile was developed for this project, making it possible to add a vent, and therefore quiet ventilation, without the façade stepping outwards.”  

MasterLine 8 POW SoftTone window in the Eurostaete residential tower. (Photography: Mitchell van Eijk)

Bespoke solution for Eindhoven’s tallest residential tower: Lighthouse

Another good example is the solution devised in collaboration with architect De Zwarte Hond and façade contractor Thermo Konstrukties for the 109-metre-high Lighthouse. To enable future residents to ventilate their homes while minimising noise, so-called harbour windows are used, with two elements connected in parallel. A special hardware solution with additional locking points was used to ensure optimal wind resistance and watertightness. Following discussions, façade contractor Thermo Konstrukties and main contractor Stam + De Koning Bouw devised a way to hoist the prefabricated frames into the façade, speeding up the construction process. “They are too large to bring in from the inside or via scaffolding,” says Bart. “The tower crane on site is used to lift them into position. Thermo Konstrukties also developed the construction equipment required for this.”

A business enquiry for Reynaers? Get in touch

Companies in this story

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • SubjectFaçade cladding
  • CompanyReynaers
Share this article

Advertisement

Follow Gevelbouw

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.