Building junctions tested for fire safety

Fermacell, part of James Hardie, has tested a large number of building junctions for fire safety in collaboration with Peutz, and showcased various models and the results at GEVEL 2020. Several fire scenarios were examined, with particular focus on fire development in the cavity.

Fermacell has long been the market leader in gypsum fibreboard for timber frame construction and has now been part of James Hardie for a year and a half.
A façade fire causes a sharp rise in temperature in the cavity, allowing the fire to spread rapidly across several storeys, says Wouter van der Velde, Head of Application Engineering at Fermacell. “Previously, it was hardly possible to see how a fire developed in the cavity, because the façade cladding obstructed the view. After testing the junctions, we found out how unpredictable a façade fire can be and what the fire does to the materials used in the HEB element. The results show that Fermacell and James Hardie products can be used to create a stable and, above all, safe façade that meets current requirements.
Fermacell has long been the market leader in gypsum fibreboard for timber frame construction and has now been part of James Hardie for a year and a half. “The synergy between the two companies means that customers have a single point of contact for questions about the complete make-up of a façade, from inside to outside. This applies to fire safety, acoustics and the structure itself,” says Van der Velde. “The series of fire tests carried out at Peutz Laboratorium voor Brandveiligheid all focused on constructions commonly used in the Dutch market. We also included all of JamesHardie’s new products.”

A façade construction with open joints, with HardieWindbreakerTM on the cavity side of the inner leaf.
Unique insights
The test rig consisted of a timber frame element, clad on the inside with 12,5 mm fermacell® Gypsum Fibreboard, and fitted on the outside with a range of different façade claddings, including James Hardie products such as HardiePlank® cladding and HardiePanel® panels. HardieWindbreakerTM was also extensively tested. “Among other things, our test sessions established the fire resistance performance (resistance to fire penetration and fire spread) of a façade construction using timber frame elements in combination with different ventilated façade claddings and claddings with open joints,” explains Van der Velde. “We tested the fire performance both from inside to outside and from outside to inside. We also carried out additional tests to assess the effect of an internal fire spreading further into the cavity. The tests also provided unique insights for Peutz, as this type of testing had not been done before. In this way, we gathered a great deal of data at junction level and can make realistic statements about fire development and the fire safety of these façade constructions.”

Standard build-up of a timber frame element with a fire-retardant membrane.
Fermacell and Peutz have included all the results in a so-called Expertpaper. Van der Velde highlights some of the key findings. “We have demonstrated with our specific solutions that a ventilated façade construction from Fermacell, James Hardie can meet a 60-minute fire resistance requirement. For a façade with open joints (greater than 6 mm) and high-performance insulation, it is advisable to provide the insulation material with extra protection using non-combustible HardieWindbreakerTM in the cavity. PowerPanel H2O produced an entirely exceptional result, remaining stable for no less than 4 hours (!) during the fire tests. We also demonstrated that the effect of PE membranes on the fire load is very limited. In short, astonishing results that we are keen to share with our customers. In any case, we can demonstrate that our solutions will prevent a disaster like the one at Grenfell Tower.”