Façade cladding

Firebarrier: why compartmentation is needed in ventilated façades

Firebarrier: why compartmentation is needed in ventilated façades

In the development of ventilated façades for high-rise buildings, there is an increasing focus on compartmentation as part of fire safety. Following the Grenfell tower fire, Minister Ollongren wrote to the municipal executive boards of all Dutch cities at the end of 2018, asking them to inspect all existing buildings for fire risks. Compartmentation is increasingly becoming a topic for discussion in new-build projects. The precast concrete and timber-frame construction industries are now looking for ways to prevent fire from spreading through ventilated cavities.

It is important to respond effectively to current and future construction technology and architectural challenges. That is what Morgo Folietechniek does. Bert Geerts, commercial director: “The Dutch Building Decree already sets requirements for fire safety, but does not yet address compartmentation. Yet it is a very good way to prevent fire spreading through the cavity. We can provide excellent advice on both the fire classification and fire performance of façades.”

morgo_2_green-25-mm-kopieren

Siderise type RH25, 90/30 for cavities up to 25mm.

FireBarrier for the concrete and timber-frame construction industries

“We are the only distributor in the Benelux to work with Siderise, which has been manufacturing barriers for the global market for many years. They developed a FireBarrier made from stone wool insulation and wrapped in reinforced aluminium foil, allowing the required ventilation within the cavity. Concrete inner leaves use horizontal and vertical barriers, while timber-frame construction uses horizontal barriers only. These are fitted with an expanding strip, which maintains airflow from the bottom to the top of the cavity. In the event of a fire, the strip expands and closes off the cavity, preventing fire from spreading through it. In timber-frame construction, the barrier is manufactured to measure for each project or as part of the system.”

morgo_3_blue-50mm-kopieren

Siderise type RH50, 60/60 for cavities up to 50mm.

Fire performance standards

“Most façade products are tested for single burning. However, you can only guarantee façade performance once the complete system has been tested. That is why we work with façade companies to test the complete system at independent fire laboratories. A European standard for fire performance in façade construction is also under consideration. For now, the British standard Bs8414 or the German industry standard Din 4102-1 is usually the benchmark.” Geerts concludes: “There is still a lot of work to be done in the Netherlands, while compartmentation is already mandatory in England and a royal decree requiring barriers in high-rise buildings is being considered in Belgium. But you can see that the market is at a turning point and demand is growing. Established façade contractors are already using them.”

Question about this story? Ask your question

Keep following this

Get an email when a new story is published. No account needed.

What you follow
  • ThemeSafe and verifiable facade construction
  • SubjectFaçade cladding
Share this article

Follow Gevelbouw

Follow

Follow a project or company and you’ll receive an email whenever a new story appears. Follow a theme or topic and you’ll receive a weekly roundup. No account or password needed: every email includes a link to what you follow.