New installation techniques for aluminium window frames ‘in mid-air’

Installing aluminium window frames is becoming increasingly complex. Windows often have to be installed before an outer skin is in place. Literally ‘in mid-air’, with no physical reference point. This has a significant impact on the process, from engineering and construction through to the installation of the joinery. Fortunately, suppliers are responding to this trend with new installation techniques.

According to Martin Hoefnagels, managing director of CS Raamconstructies and board member of the Belgian Federation of Aluminium Fabricators (FAC), the main reasons for installing windows ‘in mid-air’ are higher insulation values, which mean that the joinery is positioned at the level of the insulation layer, and shorter construction times, resulting in cost savings. “Once the windows are in and the waterproofing is in place, interior finishing and construction of the outer architectural skin can start at the same time. This means a building can be completed sooner. This trend does, of course, require more preparation from the fabricator and the contractor. The work has to be perfectly coordinated. Installing aluminium joinery has become much more challenging.”

Impact
What does this new method mean for fabricators? “We look back somewhat wistfully on the days when windows could be measured using the sill and openings already installed in the façade. Installation could also be carried out at a very high pace,” says Rita Sprangers, managing director of KA Construct and FAC board member, drawing on her experience. “Unfortunately, those days are gone. We now have to provide the support for the joinery ourselves, because the windows hang outside the façade. At the same time, we already have to take account of the complete waterproofing required for the subsequent shell construction. This new trend therefore has a considerable impact on the pace of installation and, above all, its complexity. And there is another complication: access. Windows can no longer be brought in conventionally from the inside, but have to be installed from the outside. At the preparatory stage, we must therefore also consider the erection of scaffolding, space for any lifting equipment or other aids, and safety.”

Artists
The new installation method leaves no physical reference points. “Our installers therefore have to position the window precisely in terms of height, width and depth, but in mid-air,” explains Martin Hoefnagels. “There is no reference point at all, even though the window has to align with the outer skin at a later stage. We therefore use a laser to mark out the centre lines and depth lines, allowing us to install the window to within a millimetre.” The windows are detailed and manufactured in advance based on the drawings provided. Rita Sprangers adds: “Suppose a natural stone façade is chosen. It too is dimensioned in advance and ordered to size. It’s fantastic when everything comes together on site and fits to within a millimetre. In that respect, we really are the artists of the construction chain.”

Special anchors
More and more suppliers are responding to this trend with new installation techniques, notes Marco Cannas, head of window and door technology at FAC partner Lecot. “A great deal has changed in window and door technology in recent years. Dimensions have evolved, thicker glass is being used, and so on. These developments mean that materials used five or ten years ago to install windows behind the face of the façade are no longer fit for purpose. Standard screw-in anchors are no longer sufficient, especially when the joinery has to be installed ‘in mid-air’. Fixings now need to perform different functions. They have to support the windows and preferably be adjustable too. Together with our supplier Knelsen, we have developed a range of specialist anchors based on a German system, where façades are often finished later with decorative render and installing windows ‘in mid-air’ has been common practice for years. A dedicated sill support has also been developed on this basis, incorporating thermally non-conductive material on which the windows can rest.”
Shift in responsibilities
Installing windows earlier in the construction process also shifts responsibilities. “The main contractor now has greater responsibility,” says Martin Hoefnagels. “Since we cannot measure on site, they provide us with the dimensions in advance, which we use as the basis for manufacturing the windows. And if centre lines are required, the contractor has to provide a correct starting point. In this situation, the contractor is also responsible for airtightness, as well as for preventing damage to the windows during the subsequent fit-out.”
Rita Sprangers adds: “Our responsibility has also become more explicit, particularly when it comes to positioning everything precisely to the millimetre and coordinating closely with the contractor’s critical schedule. Otherwise, the ‘production line’ comes to a halt and the construction process is delayed after all.”
Development: pre-wall installation
Alongside the specialist anchors, Marco Cannas sees another development in installation techniques. “Our supplier Triotherm has developed so-called insulation beams, available in various widths and thicknesses. Fitting the beams against the outside of the inner leaf creates a frame again, allowing the windows to be fitted very efficiently in the conventional way, but in the same plane as the insulation line. Using a draught-proofing profile means there is no need for foam sealing. It is an attractive and easy way to make both the inside and outside airtight. And in terms of responsibilities, Triotherm allows joinery installers to retain control of airtightness and waterproofing.”
A business question for Federatie Aluminium Constructeurs (FAC)? Get in touch
Companies in this story
Keep following this
Get an email when a new story is published. No account needed.
- ThemeCollaboration in the facade industry
- SubjectGeneral
- CompanyFederatie Aluminium Constructeurs (FAC)