Publication of standard for resistance to fire spread between spaces

NEN 6068, the standard for determining resistance to fire penetration and fire spread between spaces, has been revised and published. The standard has been partially revised and also includes a new informative Annex F with practical guidance and explanations.
There are several important changes:
- References for the fire resistance of solid façade elements and openings have been updated to reflect the latest version of NEN 6069+A1+C1:2019.
- The flame shapes for inclined and non-inclined façades have been better aligned.
- The flame shape for façade openings with a balcony has been standardised for balconies and overhangs with a depth of 20 cm or more.
- The formula for cooling at the walls of the fire compartment has been adapted to allow modelling of steeply inclined façades.
- The requirement for a balcony to project beyond both sides of a façade opening to prevent fire spread has been removed.
- The formula for calculating a fire compartment spanning several storeys has been simplified and improved.
- The wording on flames from a roof opening in industrial-use buildings has been adapted for adjacent fire compartments to reflect current practice.
- The standard has been amended in line with the Besluit Bouwwerken Leefomgeving (BBL), which is yet to be ratified, to require that, for new buildings, at least half of any fire resistance required for façades is provided ‘within the site boundary’ (‘from inside to outside’).
Target audience for NEN 6068
This standard forms part of the suite of standards for fire safety in buildings. The suite is divided into two parts: standards for installations, and standards for methods of determining the properties of building components, including NEN 6068. The standard is of particular relevance to architects, designers, engineering firms and consultancies.