BENG energy needs

VMRG has delivered a series of knowledge sessions for the ‘VMRG Zonwering’ community on solar shading in BENG calculations. To determine a building’s energy needs (BENG 1), a BENG calculation establishes both the heating and cooling demand for each month. These results are added together to calculate the total energy need. The calculations use monthly average values for each month.
Under the assumptions set out in NTA8800 for BENG calculations, the cooling demand in most homes accounts for less than 8% of total energy needs. As a result, measures that reduce cooling demand are less clearly reflected in BENG calculation results.
Using adjustable solar shading
Solar shading reduces solar heat gains, thereby lowering a home’s cooling demand. However, the BENG calculation also assumes that the same fractions of time when the shading is lowered apply when calculating heating demand. This increases heating demand during the shoulder seasons, as solar heat gains are reduced.
Since heating demand accounts for most of a building’s energy needs, the effect of solar shading is not clearly visible in a BENG calculation.
In practice, solar shading is a product that adapts very well to the seasons and to users’ heating and cooling needs. In winter and during the shoulder seasons, useful solar heat gains can be harnessed. On hot days, unwanted solar heat entering the building can be limited. Solar shading also blocks direct sunlight, benefiting both the thermal and visual comfort of occupants.
It is precisely this adaptive behaviour that makes solar shading an ideal way to create a good and healthy indoor climate. It is important to bear in mind that a BENG calculation is not a comfort calculation.
Solar shading in a building with cooling
When active cooling is used in a building, the system often lacks sufficient capacity to keep the home at the desired temperature throughout the season. Meeting this cooling demand with an active cooling system leads to a substantial increase in the home’s energy consumption.
With solar shading in place, active cooling can be avoided for much of the year. After all, what does not come in does not need to be removed. Combined with active cooling, solar shading has a positive effect on BENG 2. If additional cooling is still required, the cooling capacity needed will be significantly lower. This reduces the home’s energy consumption, which is particularly welcome at a time of high energy costs.