VMRG

What does BENG mean for façade construction?

VMRG directeur Hans Zwaanenburg (links) in gesprek met Rob Daniëls, adviseur bij Cauberg Huygen.
VMRG directeur Hans Zwaanenburg (links) in gesprek met Rob Daniëls, adviseur bij Cauberg Huygen.

On 18 May, Hans Zwaanenburg, director of the VMRG, spoke with Rob Daniëls, an adviser at Cauberg Huygen, about BENG during an online VMRG Expert Session.

He focused in particular on the aspects relevant to façade construction. This article covers the main topics Rob Daniëls discussed. Companies affiliated with the VMRG can watch the full Expert Session again.

The BENG requirements have been in force since January 2021. What exactly does BENG involve?
“BENG stands for ‘nearly zero-energy buildings’ and refers to the assessment method used to determine the energy performance of new and existing buildings, based on the underlying NTA 8800 standard. It applies to both residential and non-residential buildings.”

What needs to be done when applying for an environmental permit under BENG?

“The aim is to demonstrate that the building to be constructed is likely to meet the BENG requirements. Many parameters are not yet finalised at this stage, so assumptions have to be made. At completion, the building is checked to confirm that it does indeed meet the BENG requirements.”

Who carries out this type of calculation?

“To carry out these calculations, you must be certified as an individual, and the notification must also be submitted through a certified company. All scores are registered by such a company in EP-online, the national energy-label database. This is different from how EPC calculations were handled previously.”

What are BENG 1, 2 and 3?

“BENG 1 covers heating and cooling demand, in other words, a building’s energy demand. A BENG calculation is always based on monthly averages and expressed in kWh/m2 of floor area per year. Building services are entirely excluded: it is specifically about the building envelope, façade, windows and doors. BENG 2 includes the basis of BENG 1, but also takes account of building services alongside heating and cooling demand. These include systems for generating heat, cooling and domestic hot water, auxiliary energy, the type of ventilation system, solar panels and so on. BENG 3 concerns the proportion of renewable energy, such as solar energy or a heat pump.”

What affects BENG 1?

“BENG 1 focuses on the building envelope. A compact design is important. The smaller the envelope is in relation to the floor area, the better the BENG 1 scores. It is also important to consider the orientation of the glazing in relation to the sun, and the proportion of the façade that is glazed. On the one hand, you want to make use of free solar heat, but on the other, you want to limit overheating in summer. Thermal insulation matters for both opaque and transparent parts of the façade, and airtightness is another key factor. Thermal mass also plays a role. The heavier the building’s load-bearing structure, the better the BENG 1 score. Solar shading is also important, as it reduces cooling demand.”

What is TOjuli?

“TOjuli is effectively the fourth BENG requirement, but it applies only to residential buildings and is assessed at dwelling level. For TOjuli, the aim is to keep solar heat out as far as possible, for example by using solar shading, solar-control glazing or large overhangs. These measures work well in summer but can have the opposite effect in winter. Measures that are beneficial for TOjuli are therefore often detrimental to BENG 1 and 2. TOjuli does not apply where active cooling is used.”

What exactly are the BENG requirements?

“The requirements vary for different types of building. The BENG 1 factor is not fixed. It can be adjusted depending on the ratio between floor area and façade area. This applies to both residential and non-residential buildings. Different requirements apply to different building uses. Where a building combines several uses, the requirements are also combined in proportion to floor area to arrive at a single BENG requirement.”

How can façade contractors influence BENG?

“The calculation software only produces results once all the data has been entered, which makes it difficult for a façade contractor to assess. However, the BENG 1 score is very important, and we find that it is the hardest score to achieve on many projects. Improving the insulation of opaque façade elements beyond the minimum Building Decree requirements no longer delivers much of a benefit. Improvements to the transparent elements, including doors, windows and glazing, do make a difference. Façade contractors can make a real impact through the U-values of the frames and glazing, and through airtightness.”

What about the Building Decree requirement for a U-value below 1.65 W/m²K?

“That requirement is still in force, but in practice we see that the BENG 1 requirement often cannot be met with a U-value of 1.65 W/m2K.. A façade contractor therefore cannot simply adopt this as a standard U-value. The U-value for BENG 1 depends very much on the design, the size of the building, its orientation and the proportion of the façade that is glazed. In residential construction, we often find that the U-value needs to be reduced to 0.9 to 1.0 W/m2K to meet the BENG 1 requirement. Non-residential buildings often allow more leeway, and reducing the U-value is not always necessary. Every building is unique and must therefore be optimised for the specific project to meet all applicable requirements.”  

Question about this story? Ask your question

Keep following this