Quantitative determination of the air permeability of façades

Airtight construction is clearly a growing trend. Government targets for reducing energy consumption are becoming increasingly ambitious, and the related requirements are becoming ever more stringent. With today’s façade systems, manufacturing techniques and quality controls, there is no doubt that the façade industry can meet these requirements. As the requirements become more stringent, however, it is essential that windows, doors and façade elements are manufactured and installed with great care. Sometimes the smallest details can determine whether requirements are met. Imperfections in manufacture or during installation can, for example, lead to excessive air leakage and water ingress in practice.
Contracts often stipulate that an in-situ airtightness test using a blower door must be carried out before a building is handed over. This involves depressurising an entire space and determining the total air leakage through the building envelope, including all floor, wall, ceiling and other junctions. This method is highly suitable for determining the airtightness of the complete envelope and its junctions around a space. However, it is also used to make quantitative statements about the airtightness and even, after water spraying, the watertightness of windows, doors and façade elements.
Air leakage through a façade is, of course, permissible, provided the applicable standards are not exceeded.
A blower-door test can identify the largest air leaks in windows, doors or façade elements. This does not, however, mean that the façade fails to meet the applicable requirements. To establish this, quantitative measurements must be carried out on site in accordance with EN 1026 (air permeability) and EN 1027 (watertightness). The principles, equipment and procedures for these tests are fundamentally different from those of a blower-door test. These quantitative measurements can establish whether the performance requirements applicable to the project have been met.

SKG-IKOB laboratory test wall in Geldermalsen for air and water tightness testing.
Mobile test facilities for on-site testing
SKG-IKOB has mobile test facilities for carrying out quantitative measurements of the air permeability and watertightness of windows, doors and façade elements. These enable air permeability and watertightness tests to be carried out on site, both on construction sites and in completed buildings.
The façade industry also uses the test methods described in EN 1026 (air permeability) and EN 1027 (watertightness) to determine the performance achievable with different profile systems. The results are therefore directly comparable. This makes it possible to establish whether façade elements meet the specified requirements and the performance levels achievable with the façade system.
Fixed test facilities for windows, doors and curtain walls
The SKG-IKOB laboratory in Geldermalsen also has a fixed test rig for testing the air permeability and watertightness of façade elements and curtain walls. The test rig measures 5900 x 5800 mm. Windows, doors and curtain walls are tested here in a laboratory environment. The test wall can generate positive and negative pressures well above the standard values, up to a maximum of 6000 Pa. In addition to tests in accordance with EN 1026 and EN 1027, tests can therefore also be carried out at higher positive and negative pressures, allowing façades to be tested against specific, more demanding project criteria, for example.
Independent
SKG-IKOB carries out these tests as an accredited testing laboratory and Notified Body, under the independent supervision of the Dutch Accreditation Council (Raad voor Accreditatie). This guarantees and safeguards the independence and impartiality of the various tests. Through continuous development, SKG-IKOB remains at the forefront of testing and certification bodies.
SKG-IKOB has more than 50 years’ experience as a testing and certification body and testing laboratory for construction and safety products. It was founded by the industry itself to safeguard the performance and safety of products and services for the construction and property sectors in a sustainable, independent and impartial manner.