VMRG | From EPC to BENG, what does this mean for the façade industry?

On 1 July 2020, after 25 years, we will stop using EPC as the measure of buildings’ energy performance. From that date, we will switch to BENG. All new buildings, both residential and non-residential, will have to meet the Nearly Zero-Energy Buildings (BENG) requirements in permit applications submitted from 1 July 2020.
BENG indicators
From 1 July 2020, the energy performance of Nearly Zero-Energy Buildings in the Netherlands will be established using 3 requirements: BENG 1, 2 and 3.
BENG 1 is the maximum energy demand in kWh per m2 of usable floor area per year. To determine energy demand, the demand for heating and cooling is added together. This is calculated using a specified ‘neutral’ ventilation system. Energy demand can be met using renewable or fossil energy.
BENG 2 is the maximum primary fossil energy consumption, also in kWh per m2 of usable floor area per year. The difference between energy demand and primary fossil energy consumption is that primary fossil energy consumption takes account of system losses (such as heat losses from pipes), auxiliary energy (such as pumps) and the efficiency of energy generators (such as the central heating boiler). Energy demand does not. BENG 3 is the minimum share of renewable energy, expressed as a percentage. The share of renewable energy is calculated by dividing the amount of renewable energy by the total of renewable energy and primary fossil energy consumption.

BENG requirements
The table below provides an overview of the final BENG requirements for residential functions.
For BENG 1, the requirements also depend on the ratio between the heat-loss area (Als) and the usable floor area (Ag). The heat-loss area (Als) is the total area of all the building elements enclosing calculation zones, through which thermal energy is transferred to or from the external climate or to or from adjacent spaces. The usable floor area (Ag) is the area of a room or group of rooms, measured at floor level between the vertical partitioning elements enclosing that room or group of rooms. Buildings with an unfavourable ratio of usable floor area to heat-loss area, such as detached houses and patio houses, have a higher energy demand.
The final requirements for all buildings are set out in Minister Ollongren’s letter to the House of Representatives dated 11 June 2019.
Temperature exceedance requirement (TO July)
The high level of insulation in new homes creates a risk of overheating in summer. A limit is set for the temperature exceedance requirement, TO July, in homes without cooling. By announcing this requirement, it is already clear that cooling, whether passive and/or active, must be an integral part of a building’s design. Minister Ollongren (BZK) announced the limit for temperature exceedance (TOjuli) at the end of August 2019: it will be 1.0.
The new requirement to reduce the risk of overheating in new homes comes into force on 1 July 2020, at the same time as the BENG requirements.

NTA 8800
The new calculation method, NTA 8800, has been published for determining a building’s energy performance. NTA 8800 does not set requirements for the energy performance of buildings. It is a method for determining whether the requirements set out in laws and regulations have been met. NTA 8800 applies to new and existing buildings, both residential and non-residential.
From 1 July 2020, NTA 8800 replaces:
NEN 7120 “Energy performance of buildings: determination method”,
NEN 8088 “Determination method for ventilation and air permeability of buildings”, and
NEN 1068 “Calculation method for the thermal insulation of buildings”.
Implications for the façade industry
BENG 1 saves energy. High airtightness and insulation last a long time, are robust and require no routine maintenance. Investing well in BENG 1 can mean that the systems installed for BENG 2 can be smaller and simpler.
Nieman Raadgevende Ingenieurs carried out research for Lente-Akkoord into the implications of the draft BENG requirements (November 2018) for construction practice. The draft BENG requirements were calculated using NTA 8800 as the assessment method. The research focused on 12 existing projects involving ground-based homes and residential buildings. Regarding BENG 1, the report concludes that all homes meet the draft BENG requirements when the minimum requirements of the current Building Decree are applied.
Better is always possible
The BENG indicator requirements outlined above are the minimum requirements set by the government for the (improved) energy performance of buildings. These must at least be met, but better performance is always possible.